The inverter did not output and had smell of burnt of B24P2500-2
Model
BP series pure sine wave inverter 2500W 24VDC 220VAC
Description
The inverter did not output and had smell of burnt. After opening, DC input part MOS tube and fuse exploded, and DC input control board was damaged.
Fault Causes
Mostly the battery was connected oppositely.
Solutions and steps
Cannot be repaired.